● Unstable lumen size: Bore flow variations directly alter inner diameter.
● Worsening eccentricity: Changes in bore viscosity/density disrupt interfacial tension balance.
● Visual cues: Variable lumen size, pinholes, frequent breaks; too much non-solvent in bore accelerates coagulation; too little delays it.
● Key analytics: Chromatography to quantify solvent/non-solvent ratio (±5% spec); monitor bore viscosity (≤3% variation).
● Process isolation: Hold shell parameters constant, normalize bore composition; if stability returns, root cause confirmed.
● Axial heterogeneity: Pore size/porosity vary along fiber when bore composition swings.
● Event correlation: Match instability to bore system events (tank changeovers, charging).
● Online monitoring: Install inline viscometer/densitometer if feasible.
● Exclusion test: Run with known-good bore while holding others constant to isolate cause.
● Pump health: Check pulsation, seals, trapped air.