● Terminal fine filtration: before the spinneret, install high-precision filters (sintered metal or cartridge filters, 10–50 μm or finer).
● Duplex filters in parallel: standard practice. One set runs while the other is standby. When ΔP reaches the setpoint, auto valves switch to the standby set without shutdown.
● Backflushing: configure automatic backwash for sintered elements using clean solvent or compressed gas, regenerating elements and extending life.
Summary:
● Coarse (50–100 μm): basket filter, manual cleaning (upstream).
● Fine (5–20 μm): duplex bag/cartridge filters, switch without stopping.
● Final (0.5–5 μm): high-pressure candle filters or self-cleaning backwash elements (e.g., Pall).
● Alarm and auto switch when filter ΔP > 0.3 MPa.