● Control extrudate swell (Barus effect): Nonuniform shear causes twist/size instability.
● Adequate L/D: For annular slits, ensure sufficient land length; commonly L/D > 10.
● Pre-compression transition: Use gradual conical convergence into the annular gap to equalize inflow.
● CFD-guided optimization: Iterate geometry until a flat shear-rate profile at the outlet is achieved.
● Converging outlet: Conical/parabolic convergence (5°–15°) to avoid shear shocks.
● Concentric ring-gap uniformity: For bilayer dies, ring-gap tolerance ≤±2 μm around the circumference.
● Edge treatment: Micro-chamfer/radius to reduce edge-induced “sharkskin” instabilities.
● Match to rheology: Highly elastic dopes may need lower shear—use larger orifices or shorter capillaries.